Section III: Fill In The Blank  | 
| For problems 1 through 55, enter the best response (1 point each). | 
1. The Health Department recommends the pumping of septic tanks every three to  years.  | 
2. The minimum allowable wall thickness for concrete septic tanks is  inches.  | 
3. The minimum sized septic tank shall be  gallons.  | 
4. The Health Department may at any time, require any or all septic tanks to be checked for leaks by requiring tanks to be   (2 words).  | 
5. The inlet baffle should extend approximately  inches below the liquid surfaces.  | 
6. The outlet invert of the septic tank must have a minimum of  inches of fall from the tank inlet invert.  | 
7.  will be the likely outcome of a drainfield, should sludge be allowed to travel freely into it.  | 
8.  areas of the tank contain a scum layer.  | 
9. Generally, the  area of the tank contains sludge.  | 
10. For each additional bedroom in a residence, exceeding four bedrooms, the tank size should be increased by  gallons.  | 
11. The outlet baffle to the drainfield should extend (%) percent into the liquid level of the tank.  | 
12. The outlet pipe between the septic tank and the distribution box must be a solid pipe having a  pound crush strength.  | 
13. All tanks must be covered by at least  inches of soil.  | 
14. Risers must be installed on all septic tanks which are more than  inches below the finished grade.  | 
15. The septic tank contains  compartments.  | 
| 16. Separate the distribution box from the graveled drainfield trench by a minimum of   feet of solid pipe. | 
17. Sewage systems are not allowed where slopes exceed %.  | 
18. A sewage system cannot be backfilled until it has been inspected by the Health Department and  tagged.  | 
19. If a distribution box is placed so that there is a direct flow from the distribution box inlet to any drain line, a   must be installed.  | 
20. Header lines must be constructed of solid line and should be laid at a  grade.  | 
21. The minimum crush strength of drainfield pipe is  pounds crush strength.  | 
22. The maximum drainfield trench depth shall not exceed  inches.  | 
23. The minimum depth of drainfield cover is  inches.  | 
24. The minimum separation between two drainfield trenches shall be  feet, edge to edge.  | 
25. All joints of pipe and fittings should be  to hold them in place.  | 
26. What is the square footage of a drainfield that has 4 drainfield lines, each line is 67’ long and 3’ wide?  sq feet.  | 
27. Drainfield gravel must be  and be free of fines.  | 
28. All sewer lines should have a   in- stalled to clear lines of potential clogs.  | 
29. When crossing a road with a tight line the type of pipe required should be equal to or greater than  strength of pipe.  | 
30. The size of the drainfield rock must be  inches to  inches at the longest dimension.  | 
31. Distribution boxes must be  tested.  | 
32. In a four line drainfield, each line should receive % of the total flow.  | 
33. If there is public sewer within  feet of the dwelling, you may be required to connect to sewer.  | 
| 34. The covering over the drainfield trench gravel to prevent soil from entering the gravel is called  | 
35. The grade of the drainfield line shall not exceed  in  feet, while  lines are preferred.  | 
36. What is the maximum width of a drain field trench that is allowed?  feet.  | 
37.  distribution of drainfield lines is required.  | 
38. The maximum length of each gravity flow drainfield line shall not exceed  feet.  | 
39. The maximum depth of cover over a drainfield line shall not exceed  inches.  | 
40. The minimum distance between drainfield gravel and the distribution box is  inches.  | 
41. If a permit requires 900 square feet of absorption area, and you use a 3' (three feet) wide trench, 4 (four) line system, each drainfield line will be  long.  | 
42. The non perforated pipe from the building to the septic tank should be laid at  grade.  | 
43. A conventional gravity flow drainfield system requires  feet of  separation between the trench bottom and a restrictive or impermeable layer or ground water.  | 
44.  feet is the minimum distance from the septic tank to the absorption system.  | 
45.  feet is the widest drainfield trench that can be used in computation of the trench absorption area.  | 
46. There shall be a minimum of  disposal lines in a sewage waste disposal system.  | 
47. An  system must be provided on an electrical circuit separate from the pump to indicate a pump failure.  | 
48. A minimum  inches separation between the bottom of the pump chamber and the pump intake is required.  | 
49. A disconnect union that is accessible when the pump chamber is flooded and a  valve immediately on the discharge side of the pump chamber and the pump intake is required.  | 
50. If a riser is used on a pump chamber, the effluent discharge line shall exit through the  wall.  | 
51. The lid of the pump chamber shall be located  inches from the surface grade.  | 
52. The minimum riser diameter for pump chambers is  inches.  | 
53. The effluent pump chamber shall provide additional storage volume of  gallons multiplied by the number of bedrooms.  | 
54. The dosing volume shall be delivered to the drainfield within  minutes from the beginning of each cycle.  | 
55. The minimum size of a residential on-site sewage system shall not be less than  bedrooms in size nor have less than  square feet of drainfield.   |